QUESTION
Why does the scriptmonitor subcomponent (within the DGE component) stop responding. The following error message is seen in the error-date-log;
2015-05-20 00:00:13,029 m.m.ScriptMonitor[Monitor Server]: (ERROR\) heartbeat interval of 600000 exceeded
2015-05-20 00:00:18,005 m.m.ScriptMonitor[Monitor Server]: (ERROR\) heartbeat interval of 600000 exceeded
2015-05-20 00:00:23,003 m.m.ScriptMonitor[Monitor Server]: (ERROR\) heartbeat interval of 600000 exceeded
2015-05-20 00:00:27,980 m.m.ScriptMonitor[Monitor Server]: (ERROR\) heartbeat interval of 600000 exceeded
2015-05-20 00:00:32,940 m.m.ScriptMonitor[Monitor Server]: (ERROR\) heartbeat interval of 600000 exceeded
2015-05-20 00:00:37,915 m.m.ScriptMonitor[Monitor Server]: (ERROR\) heartbeat interval of 600000 exceeded
2015-05-20 00:00:42,889 m.m.ScriptMonitor[Monitor Server]: (ERROR\) heartbeat interval of 600000 exceeded
TROUBLESHOOTING
To assist with troubleshooting this issue please review the task manager and tell us if you see a number of perl scripts not terminating. In Task Manger you may enable the option to view the command line (View --> Select Columns --> Command Line)
APPLIES TO
All Traverse versions
REFERENCE
Also see How to trouble-shoot a problem with a plugin monitor